Transducers

Home /Transducers

KYOWA provides the following strain-gage based transducers for various applications.

Transducers
Type Description
LMA-A
Small-sized Compression Load Cell
The LMA-A is a compact & lightweight load cell for measuring compressive loads.
  • Rated Capacity: 5 N to 1 kN
  • Diameter: 12 mm (5 to 50 N), 20 mm (100 N to 1 kN)
  • Nonlinearity: Within ±1% RO
LMB-A
Small-sized Compression Load Cell
The LMB-A is an utra-small load cell for measuring compressive loads.
  • Rated Capacity: 10 N to 2 kN
  • Diameter: 10 mm (10 to 200 N), 16 mm (500 N to 2 kN)
  • Nonlinearity: Within ±0.5% RO
LMBT-A
Small-sized Compression Load Cell
The LMBT-A is an ultra-small load cell for measuring compressive loads. Its operating temperature is up to 100ºC.
  • Rated Capacity: 50 N to 2 kN
  • Diameter: 10 mm (50 to 200 N), 16 mm (500 N to 2 kN)
  • Nonlinearity: Within ±0.3% RO
LMR-S-SA2
Small-sized Compression Load Cell
The LMR-S-SA2 is a compact & lightweight load cell for measuring compressive loads.
  • Rated Capacity: 2 kN to 20 kN
  • Diameter: 21 mm
  • Nonlinearity: Within ±1% RO, within ±2% RO for 20 kN
LMC-A
Small-sized Compression Load Cell
The LMC-A is a compact & lightweight load cell for measuring compressive loads.
  • Rated Capacity: 5 kN to 50 kN
  • Diameter: 12±0.1mm (5, 10 kN), 16±0.1mm (20 kN), 22±0.2mm (50 kN)
  • Nonlinearity: Within ±0.5% RO for 5 kN to 10 kN, within ±1% RO for 20 kN to 50 kN
LCN-A
Small-sized Compression Load Cell
The LCN-A is a stainless-steel load cell, for measuring compressive loads. It is compact & lightweight. Excellent stability and reliability are ensured by the hermetically-sealed structure with inert gas filled in.
  • Rated Capacity: 500 N to 20 kN
  • Diameter: 50 mm
  • Nonlinearity: Within ±0.15% RO
LCX-A-ID
Small-sized Compression Load Cell
The LCX-A-ID is a stainless-steel load cell, for measuring compressive loads. It is compact & lightweight.
  • Rated Capacity: 500 N to 20 kN
  • Diameter: 28 mm (500 N to 2 kN), 43 mm (5 kN to 20 kN)
  • Nonlinearity: Within ±0.1% RO
LC-V
Small-sized Compression Load Cell
The LC-V is a compact & lightweight load cell for measuring compressive loads. It is easy installation into existing facilities. The Steady Brace ensures to cancel transverse loads resulted from horizontal displacement.
  • Rated Capacity: 50 kN to 200 kN
  • Diameter: 68 mm (50 kN), 78 mm (100 kN), 98 mm (200 kN)
  • Nonlinearity: Within ±0.05% RO
LCV-A
Small-sized Compression Load Cell
The LCV-A is a compact load cell for measuring compressive large loads. It is Easy installation into existing facilities. It is hermetically-sealed structure with inert gas filled in.
  • Rated Capacity: 500 kN, 1 MN
  • Diameter: 126 mm (500 kN), 146 mm (1 MN)
  • Nonlinearity: Within ±0.1% RO
LCR-G-SA2
Small-sized Large-capacity Compression Load Cell
The LCR-G-SA2 is a compact & lightweight load cell for measuring compressive loads.
  • Rated Capacity: 10 to 50 kN
  • Diameter: 20 mm (10 to 30 kN), 25 mm (50 kN)
  • Nonlinearity: Within ±1% RO
  • Others: Since the cable comes from the bottom, the load cells can be inserted into cylindrical objects for measurement.
LC-E
Compression Load Cell
The LC-E is a load cell for measuring large compressive loads.
  • Rated capacity: 2 MN, 5 MN
  • Diameter: 210 mm (2 MN), 240 mm (5 MN)
  • Nonlinearity: Within ±0.5% RO
  • Others: Watertight models or TEDS-installed models are available.
LC-FH
High Temp. Compression Load Cell
The LC-FH is a compressive load cell that enables to continuously operate under temperatures up to 150ºC without any external cooling.
  • Rated Capacity: 500 N to 200 kN
  • Diameter: 68 mm (500 N to 20 kN), 116 mm (100 kN), 156 mm (200 kN)
  • Nonlinearity: Within ±0.5% RO
LCK-A
Thin Compression Load Cell
The LCK-A is a compressive load cell with excellent accuracy, reliability, stability, and response.
They also have a thin design for convenient installation as detection terminals of weighing systems.
  • Rated Capacity: 5 kN to 200 kN
  • Diameter: 78 mm (5 kN to 20 kN), 98 mm (50 kN), 108 mm (100 kN), 118 mm (200 kN)
  • Nonlinearity: Within ±0.2% RO for 5 kN to 100 kN, within ±0.5% RO for 200 kN
LCH-F
High-accuracy Compression Load Cell
The LCH-F is a high accuracy load cell. It is the highest measuring accuracy in high humidity place.
  • Rated Capacity: 100 kN, 200 kN
  • Diameter: 156 mm (100 kN), 176 mm (200 kN)
  • Nonlinearity: Within ±0.02% RO
LCS-D
Explosion-proof Construction Compression Load Cell
The LCS-D is a load cell for measuring compressive loads. It can be used under environment to be subjected to explosion. For details, please contact us.
LC-J
Corrosion-resistant Compression Load Cell
The LC-J is a stainless-steel load cell for measuring compressive loads. It is corrosion resistant.
  • Rated Capacity: 5 kN to 200 kN
  • Diameter: 100 mm (5 kN to 50 kN), 120 mm (100 kN, 200 kN)
  • Nonlinearity: Within ±0.5% RO
LCW-C-SA3
Washer-type Load Cell
The LCW-C-SA3 is a thin washer-type load cell.
Rated Capacity: 10 kN to 300 kN
Diameter: 80 to 188 mm (Depends on the models)
Nonlinearity: Within ±1% RO.
LCW-D-S
Washer-type Load Cell
The LCW-D-S is a flat washer-type load cell with integrated cable fitting metal. It is high stability and capable of operating under harsh conditions.
  • Rated Capacity: 1 MN to 5 MN
  • Diameter: 241 mm (1 MN), 355 mm (2 MN to 5 MN)
  • Nonlinearity: Within ±1% RO
LCTS-B
Stainless Steel Load Cell
The LCTS-B is a stainless-steel load cell for measuring compressive loads of hoppers and weighing tanks. The built-in steady brace mechanism makes LCTS-B suitable for weighing stirring tanks or tank feet.
  • Rated Capacity: 5 kN to 100 kN
  • Diameter: 175 mm (5 kN to 30 kN), 200 mm (50 kN, 100 kN)
  • Nonlinearity: Within ±0.05% RO
LCTA-A
Thin Load Cell "Multi Force Sensor"
The LCTA-A is a thin load cell, capable of fixing on either top or bottom. It is excellent in vibration and shock resistant. It can withstand lateral loads up to 20% of the rated capacity.
  • Rated Capacity: 500 N to 3 kN
  • Diameter: 150 mm
  • Nonlinearity: Within ±0.05% RO
LCTB-A
Thin Load Cell "Multi Force Sensor"
The LCTB-A is a thin load cell, capable of fixing on either top or bottom. It is excellent in vibration and shock resistant and can withstand lateral loads up to 50% of the rated capacity.
  • Rated Capacity: 5 kN to 50 kN
  • Diameter: 200 mm (5 kN to 20 kN), 260 mm (30 kN, 50 kN)
  • Nonlinearity: Within ±0.05% RO
LCTE-A
Thin Load Cell "Multi Force Sensor"
The LCTE-A is a thin load cell, capable of fixing on either top or bottom. It is excellent in vibration and shock resistant and can withstand lateral loads up to 50% of the rated capacity.
  • Rated Capacity: 10 kN to 100 kN
  • Diameter: 148 mm (10 kN), 178 mm (20 kN, 30 kN), 198 mm (50 kN, 100 kN)
  • Ninlinearity: Within ±0.05% RO for 10 kN to 50 kN, within 0.1% RO for 100 kN
LCTD-A
Thin Load Cell "Multi Force Sensor"s
The LCTD-A is a thin load cell, capable of fixing on either top or bottom. It is excellent in vibration and shock resistant and can withstand lateral loads up to 50% of the rated capacity.
  • Rated Capacity: 100 to 300 kN
  • Diameter: 260 mm (100 kN, 200 kN), 300 mm (300 kN)
  • Nonlinearity: Within ±0.03% RO
LTZ-A
High-accuracy Tension Load Cell
The LTZ-A is a high accuracy tensile load cell with Robeval's mechanism. It is compact & lightweight.
  • Rated Capacity: 500 N to 50 kN
  • Diameter: 68 mm (500 N, 1 kN), 78 mm (2 to 10 kN), 98 mm (20 kN), 120 mm (50 kN)
  • Nonlinearity:   Within ±0.03% RO (500 N to 2 kN)
  •   Within ±0.05% RO (5 kN to 50 kN)
LT-FH
High Temp. Tension Load Cell
The LT-FH is a tensile load cell enables continuous operation under temperature as high as 150ºC with no external cooling.
  • Rated Capacity: 500 N to 50 kN
  • Diameter: 68 mm (500 N to 20 kN), 96 mm (50 kN)
  • Nonlinearity: Within ±0.5% RO
LT-FL
Low Temp. Tension Load Cell
The LT-FL is a tensile load cell enables operation at ultra-low temperature of -196ºC.
  • Rated Capacity: 500 N to 50 kN
  • Diameter: 68 mm (500 N to 20 kN), 96 mm (50 kN)
  • Nonlinearity: Within ±0.5% RO
LUX-B-ID
Compact Tension/Compression Load Cell
The LUX-B-ID is a compact stainless-steel load cell with waterproof connector for measuring tension or compression loads. Models for withstand to repeated bending (Flexible cable) are available.
  • Rated Capacity: ±50 N to ±20 kN
  • Diameter: 43 mm
  • Nonlinearity: Within ±0.1% RO for 5 kN to 20 kN, within ±0.15% RO for 50 N to 2 kN
LUR-A-SA1
Compact Tension/Compression Load Cell
The LUR-A-SA1 is a load cell for measuring tension or compression loads.
  • Rated Capacity: ±50 N to ±2 kN
  • Diameter: 28 mm
  • Nonlinearity: Within ±0.5% RO
LU-E
Tension/Compression Load Cell
The LU-E is a load cell for measuring tension or compression loads. It is hermetically-seal structure with inert gas filled in.
  • Rated Capacity: ±500 N to ±200 kN
  • Diameter: 80 mm (±500 N to ±2 kN), 100 mm (±5 kN to ±20 kN), 112 mm (±50 kN), 138 mm (±100 kN), 186 mm (±200 kN)
  • Nonlinearity: Within ±0.2% RO
LUH-F
High-accuracy Tension/Compression Load Cell
The LUH-F is a load cell for measuring tension or compression loads. It is hermetically-seal structure with inert gas filled in and excellent in zero float characteristics.
  • Rated Capacity: ±500 N to ±200 kN
  • Diameter: 100 mm (±500 N to ±5 kN), 100 mm (±10 kN to ±20 kN), 130 mm (±50 kN), 160 mm (±100 kN), 200 mm (±200 kN)
  • Nonlinearity: Within ±0.02% RO
LUK-A
Tension/Compression Load Cell
The LUK-A is a a thin load cell for measuring tension or compression loads. It can be installed to where the height is limited. It also suitable for fatigue test where repeativite loads are applied continuously.
  • Rated Capacity: ±5 kN to ±2 MN
  • Diameter: 77 mm (±5 kN to ±10 kN), 107 mm (±20 kN), 127 mm (±50 kN), 157 mm (±100 kN), 227 mm (±200 kN), 307 mm (±500 kN), 375 mm (±1 MN), 560 mm (±2 MN)
  • Nonlinearity: Within ±0.1% RO for 5 kN to 200 kN, within ±0.2% RO for 500 kN to 2 MN
LU-A
Small-capacity Tension/Compression Load Cell
The LU-A is a load cell for measuring small tension or compression loads. It use a straight beam as diaphragm.
  • Rated Capacity: ±50 to ±200 N
  • Diameter: 90 mm
  • Nonlinearity: Within ±0.3% RO
LVS-A
Ultra Small-capacity Load Cell
The LVS-A is a load cell, for measuring very small loads in the direction vertical to the mounted surface. It is easy to handle.
  • Rated Capacity: 50 mN to 20 N
  • Diameter: 35 mm
  • Nonlinearity: Within ±0.5% RO
LTS-A
Ultra Small-capacity Load Cell
The LTS-A is a load cell, for measuring very small loads in the direction parallel to the mounted surface. It is easy to handle.
  • Rated Capacity: 500 mN to 20 N
  • Diameter: 35 mm
  • Nonlinearity: Within ±0.5% RO
LUB-B
Beam-type Load Cell
The LUB-B is a beam-type load cell developed as a detector of weighing system. Models of capacity from 1kN to 20 kN are made of special stainless steel.
  • Rated Capacity: 50 N to 20 kN
  • Diameter: 42 mm (50 N to 2 kN), 67 mm (5 kN, 10 kN), 84 mm (20 kN)
  • Nonlinearity: Within ±0.03% RO for 50 N to 500 N, within ±0.05% RO for 1 kN to 20 kN
LUB-C
Beam-type Load Cell
The LUB-C is a beam-type load cell, devaloped as an OME-oriented detector of weighing system.
  • Rated Capacity: 5 kN, 20 kN
  • Diameter: 38 mm (5 kN), 53 mm (20 kN)
  • Nonlinearity: Within ±0.05% RO
LFM-A
Compact 6-component Force Transducer
The LFM-A is a 6-component force transducer. It enables simultaneous measurement of 3 components of force (Fx, Fy, Fz) in 3 axial directions and 3 moments (Mx, My, Mz) around the axes.
  • Rated Capacity: 1 kN, 3 kN
  • Diameter: 66 mm
  • Nonlinearity: Within ±0.5% RO
LFX-A
Compact 6-component Force Transducer with Built-in Amplifier
The LFX-A is a 6-component force transducer with built-in Amplifiers. It enables simultaneous measurement of 3 components of force (Fx, Fy, Fz) in 3 axial directions and 3 moments (Mx, My, Mz) around the axes. Hollowed structure for wiring easily.
  • Rated Capacity: 1 kN, 3 kN
  • Diameter: 66 mm
  • Nonlinearity: Within ±0.5% RO
LSM-B-SA1
3-component Force Transducer
The LSM-B-SA1 is a strain gage based 3-component force transducer for simultaneously measuring force in 3 directions of X, Y, and Z.
  • Rated Capacity: 10 to 500 N
  • Diameter: 88 mm
  • Nonlinearity: Within ±0.5% RO
LUR-B-SA1
Jack Load Cell
The LUR-B-SA1 is load cell for measuring loads applied to jacks.
  • Rated Capacity: ±10 kN to ±2 MN
  • Diameter: 100 mm (±10 kN), 110 mm (±20 kN), 125 mm (±30 kN, ±50 kN), 175 mm (±100 kN), 255 mm (±200 kN, ±300 kN), 330 mm (±500 kN), 430 mm (±1 MN), 530 mm (±1.5 MN), 590 mm (±2 MN)
  • Nonlinearity: Within ±0.2% RO for 10 kN to 200 kN, within ±0.5% RO for 300 kN to 2 MN
LTA-C-S
Crane Load Cell
The LTA-C-S is a crane load cell developed as detectors for jib crane weighing systems and for general tension measurement.
  • Rated Capacity: 20 kN to 500 kN
  • Diameter: 410 mm (20 kN), 430 mm (50 kN), 470 mm (100 kN), 540 mm (200 kN), 610 mm (300 kN), 670 mm (500 kN)
  • Nonlinearity: Within ±1% RO
LTR-S-SA1
One-end Revolving Tension Load Cell
The LTR-S-SA1 is a one-end revolving load cell for measuring tensile force of ropes.
  • Rated Capacity: 20 kN to 50 kN
  • Diameter: 270 mm
  • Nonlinearity: Within ±0.5% RO
LTP-S-S
Pin-type Load Cell
The LTP-S-S is a pin-type load cell for measuring crane hanging loads. It can be mounted in place of the axis of crane's pulleys.
  • Rated Capacity: 10 kN to 500 kN
  • Diameter: 50 mm (10 kN, 20 kN), 55 mm (50 kN), 60 mm (100 kN), 70 mm (200 kN), 95 mm (500 kN)
  • Nonlinearity: ±1% RO to 2% RO (Depends on user's spec.)
LCD-C
Rectangular Load Cell
Load loss due to the equipment structure, etc. is small as roll loads are received directly.
  • Rated Capacity: 20 to 150 kN
  • Diameter: 360 to 450 mm (Depends on models)
  • Nonlinearity: Within ±0.2% RO
LCR-B-S7
Tension Meter Load Cell
The LCR-B-S7 is a load cell developed for measuring loads of tension meters. It is heat resistant, oil resistant, and corrosion resistanat.
  • Rated Capacity: 5 kN to 100 kN
  • Diameter: 122 mm (5 kN to 50 kN), 208 mm (100 kN)
  • Nonlinearity: Within ±0.1% RO for 5 kN to 50 kN, within ±0.2% RO for 100 kN
BL-B
Hollowed Load Cell
The BL-B series is a hollowed load cell. It is developed to accurately measure the loads applied to earth anchors, PC anchors and the supports of tunnel arches.
  • Rated Capacity: 5 kN to 500 kN
  • Diameter: 98 mm (5 kN to 50 kN), 129 mm (100 kN), 90 mm (200 kN), 115 mm (500 kN)
  • Nonlinearity: Within ±1% RO (5 kN to 100 kN), within ±2% RO (200 kN), within ±0.6% RO (500 kN)
BL-E
Hollowed Load Cell
The BL-E is a hollowed load cell for measuring large loads applied to earth anchors, PC anchors and supports of tunnel arches.
  • Rated Capacity: 1 MN, 2 MN
  • Diameter: 140 mm (1 MN), 210 mm (2 MN)
  • Nonlinearity: Within ±0.5% RO (1 MN), within ±1.5% RO (2 MN)
BLD-A-S
Hollowed Load Cell
The BLD-A-S is a hollowed load cell for measuring loads applied to PC anchors and rock bolts. Rated Capacity: 50 kN to 500 kN
  • Diameter: 50 mm (50 kN), 61 mm (100 kN, 200 kN), 64 mm (500 kN)
  • Nonlinearity: Within ±1% RO
The BLD-A-S series is compact and lightweight hollowed load cells designed to accurately measure the load applied to a PC anchor and rock bolt. To endure field applications, these transducers feature a waterproof design and high accurately.