Strain Gages, Transducers and Amplifier Recorder
KYOWA provides a variety of instrumentations as listed below
Product image | Type | Description |
---|---|---|
![]() |
WGA-910A Instrumentation Amplifier |
・TFT LCD widens the viewing angle than before ・SD card slot (SDHC compliant) as standard equipment. ・CC-Link-compliant, easy integration in the PLC ・Numeric value registering calibration and absolute pressure measurement |
![]() |
WGA-680A Instrumentation Amplifier |
· CC-Link optional available · High-performance processing (Sampling speed: 4000 times/s, 24-bit A/D converter) · Substantial comparison functions (Extra high, high, OK, low, and extra low) · Built-in D/A converter (Sampling speed: 4000 times/s) · Display: -99999 to 99999 |
![]() |
WGA-650B Instrumentation Amplifier |
· Wide no-load zero adjustment range ±2 mV/V · High/low limit comparators · Indicated value is output in a voltage range of 0 to 10 V or in a current range of 4 to 20 mA. · Up to 4 transducers with 350 Ω bridge resistance connected in parallel. |
![]() |
WGA-710C Instrumentation Amplifier |
· Key lock to prevent wrong operation · Suitable excitation voltage for transducer can be selected · Built-in remote sensing circuit enables high accurate measurement |
![]() |
WGI-400A Instrumentation Amplifier |
· 3 sensitivity registration modes (Actual load calibration, sensitivity-registered calibration, numerical value-registered calibration) · Selectable 4 high/low limit patterns in memory · Level test with desired set-value |
![]() |
WGI-470AS1 Instrumentation Amplifier |
· High-speed sampling: 2 kHz · Simultaneously output voltage and current · 5 modes of peak hold · 3 sensitivity registration modes (Actual load calibration, sensitivity-registered calibration, numerical value-registered calibration) |
![]() |
442B-K01 Instrumentation Printer |
· Prints an index number and a channel number in 4 digits each. · Enables selection of Lister print or Texter print. · Provides approx. 250 kinds of units by input of 8-bit codes. · Power supply: 100 to 240 VAC · Provides calendar clock. |
![]() |
WGA-200A Instrumentation Amplifier |
· Voltage output, current output, and remote sensing are standard equipped. · Compact and firm · Dustproof and drip proof |
![]() |
WGA-120A Carrier Type Instrumentation Amplifier |
· Strong against inverter noise. · Output of voltage or current is switchable |
![]() |
WGA-100B Instrumentation Amplifier |
· Bridge excitation, sensitivity, calibration values and frequency response are switchable. · Available in 2 types: Manual balance and auto balance |
![]() |
WGA-101A Instrumentation Amplifier |
· Bridge excitation, sensitivity, calibration values and frequency response are switchable. · Available in 2 types: Manual balance and auto balance |
![]() |
WGC-140A 4-channel Instrumentation Amplifier |
· Up to 4 units of transducers can be connected independently to the respective amplifier circuits. · Switchable indicated values of channel to channel or the total · Analog voltage output of each channel and the total · High/low limit comparators for the total values · High-speed output suitable for control, I/O delay approx. 10 ms · Sensor check and self-test functions · Display -19999 to 19999 with decimal point anywhere |
![]() |
WDS-190AS1/191AS1 Compact Digital Indicator |
Suitable for simple measurement and checking of load, pressure or displacement transducer. The Compact Digital Indicators display and record the output data of strain-gage transducers, such as load cells, pressure transducers, displacement transducers, and torque transducers etc. |
![]() |
WDS-500BE Sensor Checker |
· Strain, I/O resistance or insulation resistance can be measured individually by pressing relative one key · Enables to output strain values · TEDS compliant · Operates on 2 pieces of AA size dry cells |
![]() |
HSC-BS Small-sized Hybrid Signal Conditioner |
· As preamplifiers of control signals for production equipment possible. · Directly be mounted to circuit boards possible · External resistors enable adjustment of bridge excitation voltage, zero balance and gain. |
![]() |
CAB-E Strain Generator |
· Generated strain level is determined by setting of 2 dials. · Remote sensing possible · No power supply is required |
![]() |
WDS-10 Strain Generator |
· Continuously generates equivalent strain with positive or negative polarity · Digital dial adopted · No power supply is required |
![]() |
SJB-C Junction Box |
· General Junction Box · For connecting extension cable of a load cell or junction of multi-load cells · Applicable cable: φ10 to φ11 (15C) |
![]() |
SJB-D Junction Box |
· General Junction Box · For connecting extension cable of a load cell or junction of multi load cells · Applicable cable: φ7 to φ8 (10B) |
![]() |
JBS-C Junction Box |
· Pressure-resistant and explosion proof Junction Box, ignition degree d2G4 · For connecting extension cable of a load cell or junction of multi load cells · Applicable cable: φ10 to φ11, please specify the cable diameter. |
![]() |
DPM-900 Series Strain Amplifier |
· Built-in HPF cancels the effect of temperature drift · Digital switch makes it easily to confirm the setting values even power off. · High voltage output of ±10 V and high SN ratio · Broad frequency response DC to 10 k Hz (913C) |
![]() |
DPM-950 Series Strain Amplifier |
· Built-in HPF cancels the effect of temperature drift · Digital switch makes it easily to confirm the setting values even power off. · High voltage output of ±10 V and high SN ratio |
![]() |
CDA/CDV-900A Signal Conditioner |
· High sensitivity (Up to 10 k times) · Fast response (Up to 500 kHz) · Long-distance testing (CDA-900A can measure up to 2 km) · Excellent nonlinearity (Within ±0.01%FS) · Universal power supply (100 to 240 VAC or 10.5 to 15 VDC) |
![]() |
DA-710A DC Amplifier |
· 2 channels per unit · Built-in LPF · Allowable common mode input 300 V and max measuring input ±110 V · With voltage calibration function |
![]() |
ERK-100 Series Telemetry Transmitter/Receiver for Strain-gage Transducers |
· Easy setting and execution. No PC required. · With functions of monitoring the status about receiving signal strength, battery remaining and communication errors · 2 antennas enables to improve the reliability of signal transmission · With analog voltage output · Battery on the transmitter can operate for up to 12 hours. |
![]() |
MRS-100 Series Digital Telemeter |
・Easy operation without PC after initial setting ・Quarter-bridge 2-wire system, 3-wire system, and full-bridge system support ・Up to 64 channels in a system ・Certified in radio law in Japan, the USA, India, Thailand, and EU ・Hours of continuous use: Max. 34 h* *When using 1ch-Strain Transmitter with two AAA-size cell, LR03EJ. |
![]() |
MCE-24A Online Conditioner System |
· 24 channels per unit · All conditioner cards are I/O isolated and easy to replace. · Interface RS-232C,or USB · Up to 20 units can be synchronized for measurement in up to 480 channels. |
![]() |
MCF-A Multi Signal Conditioner |
• No PC is required for setting and adjustment • With 4-digit switch enables to set sensor’s sensitivity value just the same as sensor's rated output • MCF-8A for 8 channels and MCF-16A channels are selectable • Capable of using for on-vehicle testing, etc. |
![]() |
CDV-400B Series Compact Signal Conditioner |
· 5 different kinds of conditioner units are available for the user's measurement purpose. · Signals of multiple units can be output from a concentrated connector. · Simultaneous calibration of all channels is possible |
![]() |
UCAM-60C M14, UCAM-65C M14 Data Logger |
Saving the long-term saving measured results to the built-in memory (Approx. 1.8 GB) USB memory ensures easy data collection Up to 1000 channels measurement with external scanners Measurement up to 20 k ×10-6 strain with a resolution of 0.1 ×10-6 strain (With full bridge system) The UCAM-60C M14 is an all-in-one measuring instrument The UCAM-65C M14 is an online data logger fully controlled from the PC |
![]() |
UCAM-550A Fast Data Logger |
· All channels simultaneous sampling · Synchronously sample at 50 Hz for 1000 channels · 5 kinds of measuring units available |
![]() |
NTB-500A Medium Speed Network Terminal Box |
· CAN interface · Large elongation of 300 k μm/m measurement · Strain, voltage, and thermocouple measuring units are available |
![]() |
NTB-100/200 Series Network Terminal Box |
· CAN data output and one cable connection · Digitized data transmission thereby strong against noise · Compact & lightweight, so easy to install on site |
![]() |
SME-30A/31A/100A/101A Handy Data Logger |
· Built-in bridge box for easy to connection strain gages · Wide measuring range ±300 k μm/m · Power supply AA batteries |
![]() |
PCD-430A Sensor Interface |
· Input signals of strain or voltage can be selected channel by channel · Synchronous sampling in 4 units connected by an optional Connection Connector Set · TEDS compliant if Input Adapter UI-10A or UI-11A is used · Max sampling frequency 10 kHz |
![]() |
PCD-400A Sensor Interface |
· Synchronous sampling in 4 units connected by an option Connection Connector Set · TEDS compliant when using Input Adapter UI-10A or UI-11A · Max sampling frequency 10 kHz |
![]() |
CTRS-100 Series Compact Recorder |
· Modular type for easy expansion and up to 128 channels · High installation and flexibility · Shock resistance: 490 m/s2 (50 G) · All channels synchronous 20 kHz (For 4 channels) Measurement of 1 channel at max. 100 kHz |
![]() |
EDS-400A Compact Recorder |
· Total 32 channels measurement possible by connecting 8 units · Synchronous sampling up to 20 kHz for 4 channels · Suitable for on-vehicle test · LAN interface |
![]() |
EDX-10 Series Compact Recording System |
· Compact & lightweight · With stacked connection, no synchronization cable is required, therefore wiring-saving. · Synchronous sampling up to 20 kHz for 4 channels · Sensors can be easily connected with input cables or input adapters. |
![]() |
EDX-100A Universal Recorder |
· Models of 1 slot, 2 slots, and 4 slots are available · LAN port for establishing multichannel network up to 256 channels · High-speed sampling at 100 kHz (10 kHz for 16-channel) · Decentralized arrangement with Synchronous Extension Units ESYN-30A is possible |
![]() |
EDX-200A Universal Recorder |
· High-speed/low-speed dual sampling Measurement of high-speed and low-speed phenomena while reducing data quantities is possible. · Built-in real-time digital filters 8th digital filters enable to acquire clear waveform · All channels synchronous sampling at 10 kHz for 32 channels (100 kHz for 3 channels) · EDX-200A-4T can operate under high or low temperature range -20 to 65ºC · One-wire synchronous (Except EDX-200A-1) Up to 8 units in decentralized arrangement for large-scale measurement is possible. |
![]() |
EDX-5000A Memory Recorder/Analyzer |
· High-speed sampling at 200 kHz/32 channels · Up to 80 input channels (EDX-5000A-80) · Simultaneous recording of measuring data and video · Conditioner cards selectable for specific applications · Effective real-time processing capability |
![]() |
EDX Series Conditioner Cards |
· Conditioner cards for EDX-100A, EDX-200A, and EDX-5000A. · EDX-5000A does not support CAN card CAN-41A. |
![]() |
EDX-200A-2H/4H/4T Option Cards |
· Optional cards for EDX-200A-2H/4H · Measurement of CAN data and GPS information · With 8-bit digital I/O |
![]() |
MCA-200A Combined G-resistant Data Logger |
· Shock resistant 196m/s2 (20G) or more · Applicable for measurement of static and dynamic phenomena alternately · A/D converter 16 bits · Max. sampling frequency is 100 kHz for 1 channel each unit, and synchronous sampling at 5 kHz for 128 channels |
![]() |
RMH-301B Digital Strain Recorder |
· Suitable for long-term measurement in the absence of personnel under the environment without external power supply · Compact & lightweight 1-channel model · Equipped with a display used to confirm setting conditions and measured values · Easy to collect data via USB memory |
![]() |
RMH-310A Digital Strain Recorder |
· Suitable for long-term measurement in the absence of personnel under the environment without external power supply · Compact & lightweight 10-channel model · Equipped with a display used to confirm setting conditions and measured values · Easy to collect data via USB memory |